SUPERCON MRI

SIGNA HD 1.5T

Specifications
Parameter
No. of Channels
8, 16
Software Versions
12X
Tyoe Of Magnet
CXK-4
Helium Boiloff
Zero Boiloff
Magnet Weight
5300kg
DIAMETRE
60CM
FOV
48CM
Gradient Amplitude
33mT/m
Slew Rate
120mT/sec
Speacial Application
GRE, SPGRE, FGRE, FSPGR, MRCP / 2d cine Angiography LAVA, Propellar. Tricks, DTI, Enhance, Inhance
Recommended
15-25 cases

SIGNA HDxT 1.5T - 16 CHANNEL

Specifications
Parameter
No. of Channels
8, 16
Software Versions
12X
Tyoe Of Magnet
CXK-4
Helium Boiloff
Zero Boiloff
Magnet Weight
5300kg
DIAMETRE
60CM
FOV
48CM
Gradient Amplitude
33mT/m
Slew Rate
120mT/sec
Speacial Application
LAVA, Propeller, Cube T2 Tricks, IDEAL, Enhance, SWAN, Perfusion, Non-contrast, Angiom, DTI, probe - 2000
Recommended
20-30 cases

SIGNA EXCITE 1.5T - 8 CHANNEL

Specifications
Parameter
No. of Channels
8
Software Versions
11X
Tyoe Of Magnet
CXK-4
Helium Boiloff
Zero Boiloff
Magnet Weight
5300kg
DIAMETRE
60CM
FOV
48CM
Gradient Amplitude
33mT/m
Slew Rate
120mT/sec
Speacial Application
GRE, SPGRE, FGRE, FSPGR, MRCP / 2d cine Angiography LAVA, Propellar. Tricks
Recommended
10-15 cases

dummy

  • A Proven, Homogeneous
  • 1.5T Magnet that Delivers a Full 48 Cm Field of View
  • Bore : 60 CM with in-bore lighting & Ventilation System
  • Table Limit : 350 lbs

SIEMENS Symphony

  • 60-cm system available in an 18- or 32-channel configuration
  • Expands upon the Symphony applications, adding additional inline processing such as Inline Diffusion for automated ADC mapping
  • Nine Tim application suites standard, including cardiac, pediatric1, and breast
  • Lightweight (patient friendly), scalable coils part of the standard configuration
  • Advanced applications standard, such as REVEAL for whole-body diffusion. For example, REVEAL can be used to detect lesions on the liver and lymph nodes
  • Low siting costs and high technology benefit smaller hospitals and imaging centers

SIEMENS Avanto

  • High diagnostic confidence due to exceptional magnet homogeneity for excellent fat saturation
  • Large 50 cm Field-of-View providing an excellent view of pathologies
  • Strong gradients for high resolution and short scan times
  • Siemens-unique TimCT technology with Continuous Table movement for CT-like scanning
  • AudioComfort reducing sound-related irritation for the patient by up to 97%1
  • Low-to-the-floor table position of just 47 cm making it accessible for a wide range of patients
  • Feet-first exams for nearly all MRI procedures (e.g. for claustrophobic patients)
  • No table movement restrictions for patients up to 250 kg

SIGNA EXCITE 1.5T - 8 CHANNEL

Specifications

Parameter

Magnet Type

Fully Open, Edddy, Current free , Self - Requlating constant Temperature Nd-Fe-B Magnet

Field Strength

0.30 T

Spectrometer

Fully Digital

Receiving Channel

4

Receiving Coils

Phased Array Coils


  • Comprehensive scanning sequences and Advanced imaging Techniques Clinical Application System.
  • Clinical Application System.
Go to top